Tiepie Engineering USB Devices Driver Download



Newest SOPAS Engineering Tool version. This download is approximately 290 MB in size and contains the Setup.exe for installing SOPAS ET. It does not contain any SDDs (SOPAS Device Drivers). SDDs can be downloaded once SOPAS ET has been started up for the first time. Use the device catalog for this purpose. The Handyscope HS3 is a powerful 100 MSa/s USB oscilloscope that can also be used as a multimeter, spectrum analyzer, data logger or protocol analyzer. This USB oscilloscope also contains a function / arbitrary waveform generator that is able to produce every signal that is needed.

This page contains archived downloads for no longer produced instruments and obsolete software. These files are no longer updated.

Contents

  • 1 Multi Channel oscilloscope software
  • 2 WinSoft measurement software
    • 2.1 Windows 32 bit
    • 2.2 Windows 16 bit
  • 3 DOS measurement software
  • 4 Manuals
  • 5 Brochures and data sheets
  • 6 Drivers
  • 7 Libraries
    • 7.1 Windows 64 bit
    • 7.2 Windows 32 bit
    • 7.3 Windows 16 bit
    • 7.4 DOS
  • 8 Unsorted

Multi Channel oscilloscope software

DescriptionVersionRemarksSize
Multi Channel software for TiePieSCOPE HS8051.33.2Windows XP/Vista/7/8/10, including PDF manual26.68 MB download

WinSoft measurement software

Windows 32 bit

DescriptionVersionRemarksSize
Handyprobe HP2 WinSoft measurement software (32 bit)2.87Windows 95/98/ME/NT4/2000/XP1.94 MB download
Handyprobe HP2 WinSoft measurement software (32 bit, USB)2.87Windows 98/ME/2000/XP1.96 MB download
Handyscope HS2 WinSoft measurement software (32 bit)2.87Windows 95/98/ME/NT4/2000/XP1.95 MB download
Handyscope HS2 WinSoft measurement software (32 bit, USB)2.87Windows 98/ME/2000/XP1.97 MB download
Handyscope HS3 WinSoft measurement software2.87Windows 98/ME/2000/XP2.11 MB download
Handyscope HS4 / HS4 DIFF WinSoft measurement software2.87Windows 98/ME/2000/XP2.17 MB download
TE6100 WinSoft measurement software (32 bit)2.42Windows 95/98/ME/NT4/2000/XP2.43 MB download
TP112 WinSoft measurement software (32 bit)2.87Windows 95/98/ME/NT4/2000/XP1.94 MB download
TP208 WinSoft measurement software (32 bit)2.87Windows 95/98/ME/NT4/2000/XP1.94 MB download
TP508 WinSoft measurement software (32 bit)2.87Windows 95/98/ME/NT4/2000/XP1.94 MB download
TP801 ISA WinSoft measurement software (32 bit)2.87Windows 95/98/ME/NT4/2000/XP2.01 MB download
TP801 PCI WinSoft measurement software (32 bit)2.87Windows 95/98/ME/NT4/2000/XP2.01 MB download
TiePieSCOPE HS508 WinSoft measurement software (32 bit)2.87Windows 95/98/ME/NT4/2000/XP1.96 MB download
TiePieSCOPE HS801 WinSoft measurement software (32 bit)2.87Windows 95/98/ME/NT4/2000/XP2.04 MB download
TiePieSCOPE HS801 WinSoft measurement software (32 bit, USB)2.87Windows 98/ME/2000/XP2.06 MB download

Windows 16 bit

DescriptionVersionRemarksSize
Handyprobe HP2 WinSoft measurement software (16 bit)2.30Windows 3.xx2.12 MB download
Handyscope HS2 WinSoft measurement software (16 bit)2.30Windows 3.xx2.14 MB download
TP112 WinSoft measurement software (16 bit)2.30Windows 3.xx2.14 MB download
TP208 WinSoft measurement software (16 bit)2.30Windows 3.xx2.17 MB download
TP508 WinSoft measurement software (16 bit)2.30Windows 3.xx2.17 MB download
TP801 ISA WinSoft measurement software (16 bit)2.30Windows 3.xx2.18 MB download
TiePieSCOPE HS508 WinSoft measurement software (16 bit)2.30Windows 3.xx2.17 MB download
TiePieSCOPE HS801 WinSoft measurement software (16 bit)2.31Windows 3.xx2.19 MB download

DOS measurement software

DescriptionVersionRemarksSize
AD128 DOS Measurement software1.0DOS protected mode, Dutch91.78 kB download
AD128 DOS Measurement software1.0DOS protected mode, English84.89 kB download
Handyprobe HP1 DOS Measurement software2.0DOS protected mode, Dutch149.20 kB download
Handyprobe HP1 DOS Measurement software2.0DOS protected mode, English147.18 kB download
Handyprobe HP2 DOS Measurement software1.0DOS protected mode, English266.25 kB download
Handyscope HS1 DOS Measurement software2.0DOS protected mode, Dutch147.22 kB download
Handyscope HS1 DOS Measurement software2.0DOS protected mode, English146.11 kB download
Handyscope HS2 DOS Measurement software1.0DOS protected mode, Dutch280.74 kB download
Handyscope HS2 DOS Measurement software1.0DOS protected mode, English277.61 kB download
TP112 DOS Measurement software1.0DOS protected mode, Dutch144.34 kB download
TP112 DOS Measurement software2.0DOS protected mode, English254.97 kB download
TP208 DOS Measurement software2.0DOS protected mode, Dutch268.14 kB download
TP208 DOS Measurement software2.0DOS protected mode, English265.09 kB download
TP5008 DOS Measurement software3.0DOS protected mode, Dutch186.61 kB download
TP5008 DOS Measurement software3.0DOS protected mode, English185.24 kB download
TP508 DOS Measurement software1.0DOS protected mode, Dutch265.75 kB download
TP508 DOS Measurement software1.0DOS protected mode, English265.73 kB download
TiePieSCOPE HS508 DOS Measurement software1.0DOS protected mode, Dutch269.40 kB download
TiePieSCOPE HS508 DOS Measurement software1.0DOS protected mode, English266.08 kB download
TiePieSCOPE HS801 DOS Measurement software1.0DOS protected mode, English281.97 kB download
µScope DOS Measurement software1.0DOS protected mode, English150.18 kB download

Manuals

DescriptionVersionRemarksSize
AD128 Instrument + DOS Software manualDutch455.63 kB download
AD128 Instrument + DOS Software manualEnglish440.99 kB download
Handyprobe HP1 Instrument + DOS Software manualDutch581.36 kB download
Handyprobe HP1 Instrument + DOS Software manualEnglish525.52 kB download
Handyprobe HP2 Instrument + DOS Software manual1.01English583.90 kB download
Handyprobe HP2 WinSoft software manual2.04Dutch481.91 kB download
Handyprobe HP2 WinSoft software manual2.04English505.11 kB download
Handyscope HS1 Instrument + DOS Software manualDutch796.31 kB download
Handyscope HS1 Instrument + DOS Software manualEnglish742.77 kB download
Handyscope HS2 Instrument + DOS Software manualDutch557.20 kB download
Handyscope HS2 Instrument + DOS Software manualEnglish519.39 kB download
TE6100 WinSoft software manual 2.2English475.01 kB download
TP112 Instrument + DOS Software manualDutch208.75 kB download
TP112 Instrument + DOS Software manualEnglish1.08 MB download
TP208 Instrument + DOS Software manualDutch211.20 kB download
TP208 Instrument + DOS Software manualEnglish1.13 MB download
TP5008 Instrument + DOS Software manualDutch637.23 kB download
TP5008 Instrument + DOS Software manualEnglish578.89 kB download
TP508 Instrument + DOS Software manualDutch1.11 MB download
TP508 Instrument + DOS Software manualEnglish1.12 MB download
TP801 ISA Instrument manual1.1English207.15 kB download
TP801 PCI Instrument manual1.0English262.32 kB download
TiePieSCOPE HS508 Instrument + DOS Software manualDutch1.19 MB download
TiePieSCOPE HS508 Instrument + DOS Software manualEnglish1.08 MB download
TiePieSCOPE HS801 Instrument + DOS Software manual1.1Dutch1.02 MB download
TiePieSCOPE HS801 Instrument + DOS Software manual1.0English918.86 kB download
TiePieSCOPE HS805 Instrument manual2.16English1.49 MB download
USB to Parallel adapter installation manualEnglish68.32 kB download
WinSoft software manual2.0.6Dutch744.24 kB download
WinSoft software manual2.0.7English705.65 kB download
µScope Instrument + DOS Software manualDutch508.30 kB download
µScope Instrument + DOS Software manual1.01English431.07 kB download

Brochures and data sheets

DescriptionVersionRemarksSize
TE6100 BrochureEnglish1.11 MB download
TP801 ISA BrochureEnglish2.02 MB download
TiePieSCOPE HS801 BrochureEnglish685.22 kB download
TiePieSCOPE HS805 BrochureEnglish1.55 MB download
USB to Parallel adapter Brochure English1.31 MB download

Drivers

DescriptionVersionRemarksSize
Handyprobe HP3 USB driver (for older software and DLLs)6.1.3Windows 98/ME/2000/XP/Vista/7/8, 32 and 64 bit526.82 kB download
Handyprobe HP2 USB to parallel adapter driver1.30.0.1Windows 98/ME/2000/XP 32 bit369.46 kB download
Handyscope HS2 USB to parallel adapter driver1.30.0.1Windows 98/ME/2000/XP 32 bit369.45 kB download
Handyscope HS4 DIFF USB driver (for older software and DLLs)6.0.8Windows 98/ME/2000/XP/Vista/7/8, 32 and 64 bit550.38 kB download
Handyscope HS4 USB driver (for older software and DLLs)6.0.8Windows 98/ME/2000/XP/Vista/7/8, 32 and 64 bit548.21 kB download
TiePieSCOPE HS801 USB to parallel adapter driver1.30.0.1Windows 98/ME/2000/XP 32 bit369.23 kB download
TiepieSCOPE HS805 USB driver6.0.7.0Windows 98/ME/2000/XP/Vista/7/8/10, 32 and 64 bit496.68 kB download
TE6100 PXI driverWindows 95/98/ME/NT4/2000/XP, 32 bit108.70 kB download
TP801 PCI driver5.2.1.0Windows 95/98/ME/NT4/2000/XP429.58 kB download
LPT/ISA DriverWindows NT4/2000/XP, 32 bit247.57 kB download
Handyscope HS3 USB driver (for older software and DLLs)6.0.8.0Windows 98/ME/2000/XP/Vista/7/8/10, 32 and 64 bit495.77 kB download

Libraries

Windows 64 bit

DescriptionVersionRemarksSize
Handyprobe HP3 Instrument DLL (64 bit)1.0.27.0For 64 bit applications on Windows XP/Vista/7/8/10 (64 bit)1.76 MB download
Handyscope HS3 Instrument DLL (64 bit)2.99For 64 bit applications on Windows XP/Vista/7/8/10 (64 bit)1.58 MB download
Handyscope HS4 / HS4 DIFF Instrument DLL (64 bit)2.99For 64 bit applications on Windows XP/Vista/7/8/10 (64 bit)1.67 MB download
TiePieSCOPE HS805 Instrument DLL (64 bit)1.30.0For 64 bit applications on Windows XP/Vista/7/8/10 (64 bit)2.07 MB download

Windows 32 bit

DescriptionVersionRemarksSize
Handyprobe HP2 Instrument DLL (32 bit)2.90Windows 95/98/ME/NT4/2000/XP458.58 kB download
Handyprobe HP3 Instrument DLL (32 bit)1.0.27.0For 32 bit applications on Windows 98/ME/2000/XP/Vista/7/8/10 (32/64 bit)746.80 kB download
Handyscope HS2 Instrument DLL (32 bit)2.90Windows 95/98/ME/NT4/2000/XP460.56 kB download
Handyscope HS3 Instrument DLL (32 bit)2.99For 32 bit applications on Windows 98/ME/2000/XP/Vista/7/8/10 (32/64 bit)711.84 kB download
Handyscope HS4 / HS4 DIFF Instrument DLL (32 bit)2.99For 32 bit applications on Windows 98/ME/2000/XP/Vista/7/8/10 (32/64 bit)790.20 kB download
TE6100 Instrument DLL (32 bit)2.51Windows 95/98/ME/NT4/2000/XP (32 bit)350.30 kB download
TP112 Instrument DLL (32 bit)2.90Windows 95/98/ME/NT4/2000/XP448.67 kB download
TP208 Instrument DLL (32 bit)2.90Windows 95/98/ME/NT4/2000/XP454.52 kB download
TP508 Instrument DLL (32 bit)2.90Windows 95/98/ME/NT4/2000/XP454.53 kB download
TP801 ISA Instrument DLL (32 bit)2.90Windows 95/98/ME/NT4/2000/XP455.87 kB download
TP801 PCI Instrument DLL (32 bit)2.90Windows 95/98/ME/NT4/2000/XP460.20 kB download
TiePieSCOPE HS508 Instrument DLL (32 bit)2.90Windows 95/98/ME/NT4/2000/XP455.22 kB download
TiePieSCOPE HS801 Instrument DLL (32 bit)2.90Windows 95/98/ME/NT4/2000/XP473.13 kB download
TiePieSCOPE HS805 Instrument DLL (32 bit)1.30.0For 32 bit applications on Windows 98/ME/2000/XP/Vista/7/8/10 (32/64 bit)1.06 MB download

Windows 16 bit

Driver
DescriptionVersionRemarksSize
Handyprobe HP2 Instrument DLL (16 bit)Windows 3.xx98.34 kB download
Handyscope HS2 Instrument DLL (16 bit)Windows 3.xx100.35 kB download
TP112 Instrument DLL (16 bit)Windows 3.xx97.00 kB download
TP208 Instrument DLL (16 bit)Windows 3.xx104.78 kB download
TP508 Instrument DLL (16 bit)Windows 3.xx104.79 kB download
TiePieSCOPE HS508 Instrument DLL (16 bit)Windows 3.xx101.83 kB download
TiePieSCOPE HS801 Instrument DLL (16 bit)Windows 3.xx107.79 kB download

DOS

DescriptionVersionRemarksSize
DOS source code archiveBasic / C / Pascal179.18 kB download

Unsorted

Engineering
DescriptionVersionRemarksSize
Matlab examplefor Matlab 6.1 and lower338.45 kB download
TiePie USB driver uninstall utilityWindows 98/ME/2000/XP379.39 kB download

A 2 channel, 100 MSa/s USB oscilloscope with function generator in a small package.

Acquisition system
  • 8, 12, 14 and 16 bit resolution, 0.2% DC vertical accuracy
  • Up to 100 MSa/s sampling, 50 MHz bandwidth
  • 128 KSamples memory per channel

Tiepie Engineering Usb Devices Driver Download Windows 7

Arbitrary Waveform Generator
  • Up to 2 MHz sine, square, triangular and arbitrary waves
  • -12 to 12 V output (24 Vpp)
  • 50 MSa/s, 14 bit, 128 KSamples arbitrary waves
  • 900 µV RMS noise level
Base model:
  • Handyscope HS3-100
  • Handyscope HS3-50
  • Handyscope HS3-25
  • Handyscope HS3-10
  • Handyscope HS3-5

The Handyscope HS3 is a powerful 100 MSa/s USB oscilloscope that can also be used as a multimeter, spectrum analyzer, data logger or protocol analyzer. This USB oscilloscope also contains a function / arbitrary waveform generator that is able to produce every signal that is needed. Together with the 2 measurement channels this oscilloscope is an excellent measurement tool to troubleshoot circuits.

Continuous streaming

Driver

Besides measuring in block mode, the Handyscope HS3 is also capable of performing continuous streaming measurements. This will create a continuous uninterrupted data stream to the computer. The data can then be displayed on the screen and/or saved to disk.

Arbitrary Waveform Generator

Tiepie Engineering USB Devices Driver Download

The integrated Arbitrary Waveform Generator operates fully independent from the measuring system of the Handyscope HS3. It has a 50 MSa/s sampling clock, a 256K samples deep waveform memory, a 14 bit output resolution and a ± 12 V output range. The arbitrary function generator allows you to generate test signals for your measurements in any shape you like. Several standard signal shapes are available and it is possible to regenerate previously measured signals.

Combining multiple Handyscope HS3s

When one Handyscope HS3 does not offer enough input channels, the Handyscope HS3 can be coupled to one or more other instruments. This allows to make a combined instrument which will enable simultaneous measuring on all channels of all combined instruments.

Download

Versatile Multi Channel oscilloscope software

The Handyscope HS3 is delivered with the versatile Multi Channel oscilloscope software, which transforms the Handyscope HS3 into an oscilloscope, spectrum analyzer, data logger, multimeter and protocol analyzer.

Some of the powerful features of the Multi Channel oscilloscope software are indicated below, for a full description of the Multi Channel oscilloscope software, refer to the Multi Channel oscilloscope software pages.

Touchscreen friendly toolbars

An oscilloscope toolbar and channel toolbars are available for each detected Handyscope. The convenient toolbars provide clear buttons for all settings of the oscilloscope and its channels. They show the current settings of the oscilloscope and allow to change all settings. The large buttons are very suitable for touchscreen operation.

The toolbars are fully configurable through the program settings. You can set the button size, add or remove buttons and change the order of the buttons.

Comprehensive Arbitrary Waveform Generator

To generate your test signals, the Multi Channel oscilloscope software also includes a comprehensive Arbitrary Waveform Generator.

An arbitrary waveform generator is an instrument that can generate repetitive or single shot signals. The signals can have a predefined standard shape like a sine wave or a square wave as in a conventional function generator. However, the signals can also have an arbitrary shape, defined by the user. These signals can be created using the Multi Channel oscilloscope software or an external program or can be signals previously measured by the Handyscope and loaded in the generator.

The Multi Channel oscilloscope software generator can be fully synchronized with the Multi Channel oscilloscope software oscilloscope, using the dedicated generator trigger signals, allowing the scope to trigger on the start of the generated signal, on each new period or on the end of the generated signal.

Flexible signal displays

The Multi Channel oscilloscope software scope, spectrum analyzer and datalogger offer an ultimately flexible way to display all aspects of the measured signals. They can have one or more graphs, each displaying one or more signals, where each graph can display different parts of a signal. Graphs can display the signal(s) of your Handyscope in Yt mode, in XY mode or as frequency spectrum, with or without interpolation. Colors of all items in a graph can be set to any required value. Graph dimensions can be adjusted to any required size, graphs can be located in one single window or in separate windows, which can be located anywhere on the desktop.

Multimeter

Driver

The multimeter in the Multi Channel oscilloscope software turns your Handyscope into a multimeter can be used to measure or monitor specific properties of a signal, like True RMS value, frequency, maximum value etc. The Multi Channel oscilloscope software multimeter can have any number of fully configurable displays, either displaying the measured value as a number or using a gauge display. When using a gauge display, it can be very helpful when adjusting a circuit for a specific property, e.g. adjusting an offset to zero.

More features

To discover more features of the comprehensive Multi Channel oscilloscope software for your Handyscope HS3, visit the Multi Channel oscilloscope software pages for a full description.

Handyscope HS3 specifications

Tiepie Engineering Usb Devices Driver Downloads

The tables below show detailed specifications of the Handyscope HS3. Jump to acquisition specifications, function generator specifications or general specifications.

Acquisition system

Number of input channels2 analog
CH1, CH2BNC
TypeSingle ended
Resolution8, 12, 14 and 16 bit user selectable
Accuracy0.2 % of full scale ± 1 LSB
Ranges (Full scale)±200 mV
±400 mV
±800 mV
±2 V
±4 V
±8 V
±20 V
±40 V
±80 V
CouplingAC/DC
Impedance1 MΩ / 30 pF
Maximum input voltage (in all ranges)200 V (DC + AC peak < 10 kHz)
Maximum input voltage 1:10 probe (in all ranges)600 V (DC + AC peak < 10 kHz)
Bandwidth (-3dB)DC to 50 MHz maximum
AC coupling cut off frequency (-3dB)1.5 Hz
Maximum sampling rateHS3-100HS3-50HS3-25HS3-10HS3-5
8 bit100 MSa/s50 MSa/s25 MSa/s10 MSa/s5 MSa/s
12 bit50 MSa/s50 MSa/s25 MSa/s10 MSa/s5 MSa/s
14 bit3.125 MSa/s3.125 MSa/s3.125 MSa/s3.125 MSa/s3.125 MSa/s
16 bit195 kSa/s195 kSa/s195 kSa/s195 kSa/s195 kSa/s
Maximum streaming rate10 kSa/s
Sampling clock source
InternalQuartz
Accuracy±0.01 %
Stability±100 ppm over -40 °C to +85 °C
Time base aging±5 ppm/year
ExternalExtension connector
Memory
8 bit256 Kpts channel
12, 14, 16 bit128 Kpts per channel
Trigger
SystemDigital, 2 levels
SourceCH1, CH2, AND, OR, digital external, generator start, generator new period, generator stop
Trigger modesRising edge, falling edge, inside window, outside window
Level adjustment0 to 100 % of full scale
Hysteresis adjustment0 to 100 % of full scale
Resolution0.025 % (12 bits)
Pre trigger0 to 128 KSamples, 1 sample resolution
Post trigger0 to 128 KSamples, 1 sample resolution
Digital external trigger
InputExtension connector
Range0 to 3.3 V (5 V max)
CouplingDC

Arbitrary Waveform Generator (independent from acquisition system)

WaveformsSine, triangle, square, DC, noise and arbitrary
Number of output channels1 analog, BNC
DAC resolution14 bit @ 50 MSa/s
Output range-12 V to 12 V
Amplitude
Range0.12 V1.2 V12 V
Resolution13 bit
Accuracy0.4 %
DC offset
Range-12 V to 12 V
Resolution13 bit
CouplingDC
Impedance50 Ω
BandwidthDC to 2 MHz
Noise level0.12 V range
900 µV RMS
1.2 V range
1.3 mV RMS
12 V range
1.5 mV RMS
System characteristics
SystemDDS
Memory256 KiSamples
Maximum Sampling rate50 MHz
Sampling sourceinternal
Accuracy±0.01 %
Stability±100 ppm over -40 °C to +85 °C

Interface

InterfaceUSB 2.0 High Speed (480 Mbit/s); (USB 1.1 Full Speed (12 Mbit/s) and USB 3.0 compatible)

Power Requirements

Power from USB port500 mA max (2.5 W max)
Power via external power input / extension connector1500 mA max (7.5 W max)
Minimum voltage4.5 VDC
Maximum voltage (SN# <12941)6 VDC
Maximum voltage (SN# >12941)12 VDC

Physical

Instrument height25 mm (1 inch)
Instrument length170 mm (6.7 inch)
Instrument width140 mm (5.2 inch)
Cord length1.8 m (70 inch)
Weight480 g (17 ounce)

I/O connectors

Channel 1, 2BNC
GeneratorBNC
USBfixed cable with USB 2.0 and USB 1.1 type A connector
Extension connectorD-sub 25 pins female

System requirements

PC I/O connectionUSB 2.0 High Speed (480 Mbit/s); (USB 1.1 Full Speed (12 Mbit/s) and USB 3.0 compatible)
Operating systemWindows Vista/7/8/10

Operating environment

Ambient temperature0 to 55°C
Relative humidity10 to 90%, non condensing

Storage environment

Ambient temperature-20 to 70°C
Relative humidity5 to 95%, non condensing

Certifications and Compliances

CE mark complianceyes
RoHSyes

Package

InstrumentHandyscope HS3
Oscilloscope probes2 x Oscilloscope Probe 1:1-1:10 - HP-3060
Accessoriesexternal power cable for second USB port
Softwarefor Windows 7/8/10, via website
Driversfor Windows 7/8/10, via website
Manualsinstrument manual and software user's manuals
color printed and digital, via website

Options

Optionally available10 MHz generator output

Tiepie Engineering Usb Devices Driver Download Windows 8.1

The Handyscope HS3 is available in five models with different maximum sampling speeds.

Order codeMax. sampling speed
HS3-AWG-100100 MSa/s
HS3-AWG-5050 MSa/s
HS3-AWG-2525 MSa/s
HS3-AWG-1010 MSa/s
HS3-AWG-55 MSa/s

Available options for the Handyscope HS3 are:

  • W5: With the extended warranty option, warranty is five years on parts and labor. Without this option, the models have two years warranty on parts and labor.

The Handyscope HS3 is delivered with:

InstrumentHandyscope HS3
Probe2x Oscilloscope Probe 1:1-1:10 - HP-3060
Accessoriesexternal power cable for USB port
Softwarefor Windows 7/8/10, via website
Driversfor Windows 7/8/10, via website
Manualsinstrument manual and software user's manuals
color printed and digital, via website

Several downloads for the Handyscope HS3 are listed below, including Multi Channel oscilloscope software, drivers and manuals.

Driver & Software

DescriptionVersionRemarksSize
USB driver8.1.9Windows 10, 32 and 64 bit3.80 MB download
Multi Channel software1.43.4Windows 10, 32 and 64 bit, including PDF manual91.76 MB download

Manuals & Documents

Tiepie Engineering Usb Devices Driver Download Windows 10

DescriptionVersionRemarksSize
Multi Channel software manual 1.07English4.86 MB download
Handyscope HS3 Instrument manual2.27English448.52 kB download
Handyscope HS3 Application note1English973.83 kB download
Handyscope HS3 BrochureEnglish3.84 MB download
Handyscope HS3 Data sheetEnglish1.41 MB download

Software Development Kit (SDK)

Interfacing the Handyscope HS3 with third party software and developing own software requires the LibTiePie Software Development Kit. Detailed information on the LibTiePie SDK, downloads for Windows and Linux platforms and bindings and programming examples for various programming environments can be found in the LibTiePie pages.